Dominevo
Notifications

Batteries, consumables and tanks

Get told about offline devices, low batteries, worn filters and robot-vacuum tanks, either instantly or in a scheduled summary.

This page shows how to build one rule that tells you when anything in the house needs a battery, a filter or an empty tank — and not about the thermometer that has read 0 % for a year.

These are Device events rules (admin-only in the app). Create one with Rules → Device events → New device-event rule (admin UI) or New rule → Devices (app), then tick the events.

The events

GroupEventsFires when
Device stateDevice offline / online, switched off / onThe hub loses or regains a device — any type, not just cameras. Switched off is a person turning it off, never a fault.
StreamsStream offline / onlineA camera stream stops or comes back.
BatteryBattery low / back to normalA measured battery crosses the low threshold.
ConsumablesConsumable low / replacedA filter, brush, bag or mop pad reaches this rule's threshold, or the device says it is due.
TanksTank low / full / back to normalA robot vacuum reports clean water or detergent low, or dirty water or the dust bin full.
Detecting nothingCamera detecting nothingA camera that is up and analysed has produced no detection for a long time.

Narrowing them

FilterUse
Only these devicesWatch a few devices only. Empty = every device.
Never these devicesApplied after the list above: a device here is never reported, whatever else matches. "Every battery except the thermometer that always reads 0 %."
Only these device typesCamera, sensor, switch, container… "Tell me only about cameras going offline."
Consumable low at (%)This rule's consumable threshold (below).

Do not narrow battery or consumable alerts by device type "camera". Batteries and consumables belong to sensors, containers, vacuums and mowers — rarely to a camera — so that filter silences almost all of them. Both editors warn when a rule does this. If you want "only cameras" for offline alerts and "everything" for batteries, make two rules.

Filters apply only to the events they make sense for, so one rule can safely mix them: a device-type filter narrows the device, battery, consumable, tank and detecting-nothing events and is ignored by stream events; the consumable threshold is ignored by everything but consumables.

Batteries

The threshold, the reminder and the all-clear are cluster-wide settings, not per rule: two rules disagreeing about when a battery is low would be worse than one answer. They are in the Pipeline Analytics addon's settings, section Battery & offline alerts.

SettingDefault
Low battery at20 %At or below this, a measured battery is low.
Repeat while still true720 min (12 h)How long before a still-flat battery — or a still-offline device — is announced again. 0 says it once. The repeat goes through the same rules, mutes and schedules as the first.
Announce the all-clearonSend back to normal / online when it recovers. Off hides the message only; the next fall is still announced.
  • The alert fires once when the battery enters the low band, and clears only when the reading is well clear of it — a battery sitting on the threshold does not send pairs of notifications.
  • A device with a yes/no low-battery indicator (no real percentage) is judged by the indicator; the threshold does not apply to it.
  • A device that has never reported a level is never announced as flat.

Consumables

Unlike the battery threshold, a consumable's threshold is each rule's own: Consumable low at (%), 1–95, default 15.

A rule at 25 is told about a filter at 20 %; a rule at 10 is not — and is told later, when the filter reaches 10 %. Each rule has its own episode, reminder and recovery (the replaced event fires once the item is 5 points above the rule's threshold, typically after you fit a new one). A device that only says "replace", without a percentage, is low at every threshold.

{{item}} and {{percentage}} put the item and its remaining life in your own wording.

Tanks

A robot vacuum's tanks — clean water, detergent, dirty water, dust bin — report low or full from the device's own sensor; Dominevo has no threshold of its own for them. A change has to hold for a minute before it counts, so a sloshing float does not notify. Both low and full recover into one back to normal. {{tank}} names which tank.

An alert nobody heard is kept

If a battery goes low while no rule would deliver it — every matching rule is outside its schedule, say, or you have not created one yet — the alert is not thrown away. It stays pending and is offered again when your rules change, and at the repeat interval (hourly when repeats are off). A raise refused only by a schedule is therefore delivered when the schedule opens. A pending alert whose device recovers in the meantime sends nothing.

Scheduled state summary

Instant alerts are right for a flood; for batteries and updates you may prefer one message at a time you choose that lists what is true right now. A Device events or System rule can be switched from Instant (the default) to Summary on schedule.

  • When it is sent — at the end of each window of the rule's schedule, set as send at HH:MM on these days, with the same time zone and days as any other schedule. It is sent once per window, including across a restart.

  • What it contains — the current state of the rule's events, after the rule's own filters (devices, excluded devices, device types, nodes, packages, consumable threshold), in sections: batteries low (device, %); consumables to replace (device, item, %); tanks low or full; devices and streams offline, and since when; cameras detecting nothing; nodes offline; updates available (package and version, per node). Things that have already recovered do not appear.

  • One notification per category when you ask for it. Tick One notification per category on the rule, and each group with something to report arrives as its own notification in the same window, titled with the group and a count, such as Low batteries: 2. A long evening summary then does not bury the tank that needs emptying. The groups are:

    • for a Device events rule: Offline or off, Streams offline, Low batteries, Consumables to replace, Tanks low, Detecting nothing;
    • for a System rule: Nodes with problems, Addons stopped, Addon updates and Server updates. Server updates include container updates.

    The two update groups list their updates under one heading per node, the hub first, so you can see at a glance what to apply where. Tapping Nodes with problems or Server updates opens the cluster page of the admin UI; tapping Addon updates opens the addons page.

  • Nothing to report sends nothing for that category. If one section cannot be read at that moment, the summary says that section is unavailable rather than leaving it out silently.

  • In summary mode the rule sends no instant notifications for its events. Other rules on the same events are unaffected.

  • It is delivered like any notification: to the rule's targets, with its template, recorded in the history, subject to snooze and mute. Test on a summary rule sends the current summary immediately.

  • Alarm rules cannot use it — the alarm always notifies at once.

Conditions with a problem and a recovery

A condition that has a problem and a recovery — devices, streams and nodes going offline and back, a device switched off and on, batteries, consumables, tanks, recording health, storage space, critical alerts, rule health — is one entry in the rule's event list, not two.

  • On an instant rule, ticking it means both the problem and the recovery, so you are never told something broke and not that it came back. Recovery messages read as recoveries (back online, recording again).
  • On a summary rule, ticking it means what is in the problem state at the scheduled time, labelled as a snapshot (for example Streams offline now). The summary sends what is wrong, not each change.
  • Recording health, storage space, critical alerts and rule health have no state to snapshot; the editor says so on a summary rule, and the summary reports nothing for them.

Then