Value history
What Dominevo records about a device over time, how long it keeps it, how to change retention, and where the graphs appear.
Value history is the record of what a device reported over time: a thermostat's temperature, a dishwasher's power draw, a door's open and closed periods, a camera's motion. Dominevo keeps it for you, draws it as graphs, and lets other features such as statistics and integrals read it.
What is recorded
Dominevo records a reading when the device's capability declares it worth keeping. A capability does this once, for every device that has it, so you do not choose readings one by one. Four shapes exist:
| Shape | Example | How it is drawn |
|---|---|---|
| Gauge | Temperature, humidity, power, battery | A line |
| Counter | Energy in kWh | Bars, with the total for the window |
| On/off | Online, door open, motion | A timeline of on and off periods |
| Choice | A dishwasher's program state | A timeline of states, with the time spent in each |
To keep the record small, a gauge is stored when it changes by more than a small margin, and not more often than every ten seconds. A slow drift still adds up, because each reading is compared to the last one stored.
A camera also records what its analysis produces: motion events, audio level and, per zone and object class, how many objects are present.
Devices that are only containers for other devices, and hubs, are not recorded; their children are.
How it is kept
Readings are stored in layers, each summarising the one before:
| Layer | Holds | Kept for (default) |
|---|---|---|
| Raw points | Every stored reading | 7 days |
| 5-minute | One summary per 5 minutes | 30 days |
| 1-hour | One summary per hour | 365 days |
| 1-day | One summary per day | Forever |
A summary has the average, the minimum and the maximum of the period; the average is weighted by how long each value was in force, so a value that held for 4 minutes counts for more than one that held for 1 second. A graph picks the finest layer that still covers the window you asked for, which is why a one-year graph is smooth and fast.
Enable and configure
Value history is a built-in part of the hub and is on by default for every real device; there is nothing to switch on per device in the admin UI.
To change how long each layer is kept, open History in the sidebar
(/system/history) and edit its Retention card:
| Setting | Meaning | Default | Limit |
|---|---|---|---|
| Raw points (days) | How long every stored reading is kept | 7 | 1 to 60 |
| 5-minute rollup (days) | The 5-minute layer | 30 | |
| 1-hour rollup (days) | The 1-hour layer | 365 | |
| 1-day rollup (days) | The 1-day layer; 0 keeps it forever | 0 |
Older data is removed every ten minutes. Shortening a layer deletes what falls outside it on the next pass; lengthening it only affects what is recorded from then on.
Backups. The history lives in its own database, History (statistics). A backup carries it only when you tick it in the backup's database picker; the default nightly backup carries configuration only, and a weekly archive of the statistical databases is set up once on a hub that backs up somewhere. See Backup.
Where it is shown
A device's History tab
Every device page has a History tab. It shows one section per capability, with a chart per unit: a thermostat's current and target temperature share one chart, its humidity and battery have their own.

The bar at the top chooses the window: 24 h, 7 d, 30 d, 1 y or a Custom range. Compare with previous period draws the previous window of the same length beside the current one.
Choices and on/off values are drawn as timelines. The totals under a timeline are exact, for example "running 3 h 20 m", whatever the window.

On a phone the tab sits below the live card and the charts stack.

A camera's Live Stats tab
A camera shows the same charts on its Live Stats tab, fixed to the last 24 hours: motion events, audio level and occupancy per zone and object class.
System → History
System → History puts series from any devices or nodes on one graph, so you can compare a room's temperature with the radiator's target, or a dishwasher's power with the house total. Search the list by device, room, metric or unit, tick up to 24 series, and the overlay draws them with one axis per unit.

Save as panel keeps the current selection under a name, shown as a chip above the list for one click next time. Panels are saved per account. The page also lists series whose device has been removed, with a Review button, so you can see what is left behind.
Using the history elsewhere
- Build-your-self statistics and integrals read the recorded series, for example the energy used over a day. They read the layer whose retention covers the window, and they do not fill a gap with zero.
When a graph is empty
A capability that declares no history records nothing. If a reading does not appear on the History tab, its integration has not declared it.
Gateways and other types
The gateway, hub, container, workload, media player, update, image, control, notifier, script, automation and generic device types.
Overview
Publishing your Dominevo cameras and devices to Apple Home, Alexa and Home Assistant — where the exporters live, how you choose what each one receives, and which one to pick.