Dominevo
Troubleshooting

Overview

Symptom-first triage — no video, no detections, high CPU, nothing recorded, no notifications — and where the logs are.

Find your symptom. Each entry lists causes in the order they are actually worth checking, not in the order they are interesting.

Before anything else: Administration → Logs is a live, filterable, per-addon view. It answers most of what follows faster than reasoning does.


The admin UI does not load

Check the container is running and past its start. A genuine first boot seeds addons and pulls models; the UI answers before that finishes. docker compose logs -f dominevo shows you where it is.

Check you used https and the machine's IP, not http, not localhost unless you are sitting at the machine. Port 4443.

Accept the certificate. A fresh install is self-signed and your browser will refuse until you say so.

A blank page that was working before is a stale cached application. Reload with cache bypass — Dominevo also detects this and reloads itself, but not instantly.


A camera shows no video

In this order:

1. Is it idle, or is it in error? idle is healthy — it means nothing is watching, so Dominevo is not connected. Only error is a fault, and its message is the thing to read.

2. Can the machine reach the camera? From the host, not from your laptop. Different VLAN, wrong subnet, and Docker bridge networking all produce exactly this symptom. The shipped compose file uses host networking for this reason.

3. Credentials. Some cameras cap concurrent sessions per account — if the phone app is logged in with the same account, Dominevo can be the one refused. Give Dominevo its own account.

4. The stream URL, if you added it by RTSP. Try it in VLC from the same machine. If VLC cannot play it, Dominevo cannot either.

5. Try a different stream. Where a vendor publishes several sources, assign a different one to the slot. A native path failing while the plain-RTSP mirror works is informative.


Live view connects but the picture is blank

This is almost always H.265. The connection succeeds, the tile stays black, and nothing errors.

  • Same camera works on another machine? Your browser has no hardware HEVC decoding. Publish an H.264 stream from the camera.
  • Works at home, blank remotely? The media path never established. Configure TURN; see Network troubleshooting.

See Live view.


Nothing is being detected

Is detection enabled on that camera, and in which mode? on-motion is the default — if motion is not firing, detection never runs. Check motion first.

Is motion firing? If the camera is set to use its own firmware motion and that is misconfigured on the camera, Dominevo gets nothing. Switch to the software analyzer temporarily to separate the two.

Did you draw a zone recently? A single include rule turns off the rest of the frame for that stage. This is the most common cause of detection stopping abruptly. See Zones.

Is the confidence threshold too high? Lower it and watch.

Is the detection stream too small? Distant and small objects vanish on a low-resolution stream. See Streams.

Is detection slow (hundreds of milliseconds per frame)? It is running on the CPU: no accelerator reached the container. Run npx dominevo host-check on the host; it prints the image tag and the device flags to add.


Too much is being detected

Do not raise the confidence threshold first. Most false detections are real objects in a place you do not care about, and raising the threshold makes you miss real things elsewhere.

Draw an exclude zone at the motion stage. Cheapest and most effective.

Add a class filter — "ignore people in the street, keep vehicles".

Then consider the threshold, in small steps, checking between them.


CPU is pinned

Separate decode from inference before changing anything. Turn detection off on every camera and look at what remains. That is decode. See Hardware acceleration.

Is /dev/dri passed through? Run npx dominevo host-check on the host (or inside the container): it lists the accelerators found, whether each one reached the container, and the exact flags to add. Software decode of a few 4K HEVC cameras costs roughly 60 % of a CPU on its own.

Is detection on the high slot on every camera? Moving it to mid is the largest single saving available.

Is anything set to always-on that does not need to be?

Are classifiers enabled on cameras that do not need them?


The container keeps crashing

Check pids_limit. A container's limit counts threads; Docker's 2048 default was measured refusing thread creation on a busy hub. It should be 8192.

Check declared devices exist. Docker refuses to start a container that declares a device the host does not have — which is why /dev/dri and /dev/accel ship commented out.


Nothing is being recorded

Is the camera's recording mode set? Off is the initial state.

Is a schedule excluding right now? A band that ends before it starts wraps past midnight; make sure yours means what you think.

In events mode, is the trigger firing? No motion, no recording.

Is DOMINEVO_MEDIA_ROOT set? Mounting /recordings does nothing on its own. The symptom is /data growing while /recordings stays empty.

Is the volume above its free-space guard? Once a location is too full, Dominevo stops writing to it.


Recordings disappeared

Retention deleted them. It is enforced and there is no undo. Check the camera's maximum age and maximum size, and the node default it inherits.

Check whether the event survived. Events are stored independently of footage, so the event list keeps its shape after the video has aged out. An event whose clip will not play is usually this.


No notifications arrive

Is the rule enabled, and is its schedule live right now?

Is it an identity or plate rule on an immediate trigger? Those fire on a fresh detection, before enrichment has run, and a condition needing data the record does not carry fails rather than passes. Switch on Wait for recognition, or move it to track end.

Is the cooldown swallowing it? Sixty seconds by default.

Test the delivery target on its own, so you know whether the problem is the rule or the channel.

The full checklist, starting from the delivery history, is in Why didn't I get it?.


Faces are detected but never named

Expected, until several bars are cleared. In order of likelihood:

The identity has one enrolled sample. Single-sample identities are excluded from automatic matching. Enrol at least two, ideally more.

The face is too small. Below roughly 48 pixels across, faces are collected but never auto-named — the signature is unreliable at that size.

The match was close but not conclusive. It appears as a suggestion to accept or reject rather than as an assignment.

See Enrichments.


Where to look

Administration → LogsLive, per addon, filterable. Start here.
Cluster → AddonsWhat is installed on each node, and what failed.
Cluster → NodesNode health. See Cluster troubleshooting.
The camera's pageStream slot status and per-camera state.
docker compose logs -f dominevoBoot problems, before the UI is up.

When you report a problem

Include: what you expected, what happened, the camera's integration and model, whether it works on the LAN and not remotely (or the reverse), the relevant log lines, and whether it ever worked. "It stopped working after I changed X" is worth more than any amount of description.