heat-pump-status
Heat pump status: the one main, READ-ONLY cap of a heat pump.
Heat pump status: the one main, READ-ONLY cap of a heat pump. Every circuit the gateway reports is an entry of circuits[] — heating, hot water, cooling or solar, any number — so no circuit needs a device of its own to be seen. The settable parameters are typed methods of heat-pump-control; the values they take and their limits (allowed, min, max, step) are read from the gateway and carried here, never written in code.
A value the gateway did not report is null, never 0. The COP is not a field: it is computed from the two powers at read time ({
The kinds of circuit a heat pump serves.
At a glance
| Capability | heat-pump-status |
| Provided by | The device's own driver provides it: each device registers its own provider. |
| Active providers per device | one |
| Device types | heat-pump |
| Source | packages/types/src/capabilities/heat-pump-status.cap.ts |
Methods
This capability declares no methods.
Runtime state
The state Dominevo keeps for each device with this capability, readable without calling the provider.
| Field | Type | Required | Description |
|---|---|---|---|
circuits | ({ id: string; kind: "heating" | "dhw" | "cooling" | "solar"; label: string; icon: binary or opaque value; currentTemp: number | null; targetTemp: number | null; mode: string | null; active: boolean | null; operationMode… | yes | |
system | { silent: { value: string | null; allowed: string[] } | null; away: { value: string | null; allowed: string[] } | null; additionalHeater: { value: string | null; allowed: string[] } | null; holiday: { value: string | nul… | yes | |
power | { thermalW: number | null; electricalW: number | null; compressorPct: number | null } | yes | |
temperatures | { supply: number | null; return: number | null; outdoor: number | null } | yes | |
energy | { thermalKwh: number | null; electricalKwh: number | null } | yes | |
waterPressureBar | number | null | yes | Water pressure of the heating loop, bar. |
starts | number | null | yes | Compressor starts since commissioning. |
lastFetchedAt | number | yes | Ms epoch when the slice was last read from the gateway. |