heat-pump-control
Heat pump settable surface: one typed method per parameter, never a generic set(key, value).
Heat pump settable surface: one typed method per parameter, never a generic set(key, value). The values a mode takes and the limits of a number are the ones heat-pump-status carries (allowed, min, max, step), read from the gateway; a provider refuses a value outside them. The state is heat-pump-status — this cap has none.
At a glance
| Capability | heat-pump-control |
| Provided by | The device's own driver provides it: each device registers its own provider. |
| Active providers per device | one |
| Device types | heat-pump |
| Source | packages/types/src/capabilities/heat-pump-control.cap.ts |
Methods
Every method takes the device id (deviceId) to address the device; the input tables below list the other fields.
| Method | Kind | Required of a provider | Access |
|---|---|---|---|
setSilentMode | mutation | yes | protected |
setAwayMode | mutation | yes | protected |
setAdditionalHeaterMode | mutation | yes | protected |
setHolidayMode | mutation | yes | protected |
setCircuitOperationMode | mutation | yes | protected |
setCircuitHeatCoolMode | mutation | yes | protected |
setCircuitSummerWinter | mutation | yes | protected |
setCircuitComfortSetpoint | mutation | yes | protected |
setCircuitEcoSetpoint | mutation | yes | protected |
setCircuitMaxFlowTemp | mutation | yes | protected |
setDhwOperationMode | mutation | yes | protected |
setDhwTemperatureLevel | mutation | yes | protected |
setDhwChargeDuration | mutation | yes | protected |
startExtraHotWater | mutation | yes | protected |
setSilentMode
mutation
System modes — each independent, each with its real values. off / auto / on.
Input
| Field | Type | Required | Description |
|---|---|---|---|
mode | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.silent | Set silent mode |
setAwayMode
mutation
off / on.
Input
| Field | Type | Required | Description |
|---|---|---|---|
mode | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.away | Set away mode |
setAdditionalHeaterMode
mutation
off / manual / auto.
Input
| Field | Type | Required | Description |
|---|---|---|---|
mode | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.additionalHeater | Set additional heater |
setHolidayMode
mutation
off / hm1 .. hm8 (the programmes the gateway lists).
Input
| Field | Type | Required | Description |
|---|---|---|---|
mode | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.holiday | Set holiday mode |
setCircuitOperationMode
mutation
Per circuit.
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes | |
mode | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.circuitOperationMode | Set circuit operation mode |
setCircuitHeatCoolMode
mutation
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes | |
mode | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.circuitHeatCoolMode | Set circuit heat / cool |
setCircuitSummerWinter
mutation
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes | |
mode | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.circuitSummerWinter | Set circuit summer / winter |
setCircuitComfortSetpoint
mutation
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes | |
temp | number | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.circuitComfortSetpoint | Set comfort temperature |
setCircuitEcoSetpoint
mutation
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes | |
temp | number | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.circuitEcoSetpoint | Set eco temperature |
setCircuitMaxFlowTemp
mutation
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes | |
temp | number | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.circuitMaxFlowTemp | Set maximum flow temperature |
setDhwOperationMode
mutation
Hot water.
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes | |
mode | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.dhwOperationMode | Set hot water mode |
setDhwTemperatureLevel
mutation
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes | |
level | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.dhwTemperatureLevel | Set hot water level |
setDhwChargeDuration
mutation
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes | |
minutes | number | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.dhwChargeDuration | Set hot water charge duration |
startExtraHotWater
mutation
Start an extra-hot-water charge now: an action, not a stored mode.
Input
| Field | Type | Required | Description |
|---|---|---|---|
circuitId | string | yes |
Output
Nothing.
Actions (offered in automations and on device cards)
| Action | Label | Sets |
|---|---|---|
heatPump.extraHotWater | Start extra hot water |