ReferenceHTTP API
heatPumpControl
The heatPumpControl router: 17 methods of the heat-pump-control capability, with tier, scope, input and output.
Capability heat-pump-control · scope device · mode singleton · source packages/types/src/capabilities/heat-pump-control.cap.ts:56.
Every method is called at /trpc/heatPumpControl.<method> — queries with GET, mutations with POST. See How to call and Authorization. Device methods take deviceId in their input.
| Method | Kind | Tier | Token scope | Viewer |
|---|---|---|---|---|
setSilentMode | mutation | protected | create | yes |
setAwayMode | mutation | protected | create | yes |
setAdditionalHeaterMode | mutation | protected | create | yes |
setHolidayMode | mutation | protected | create | yes |
setCircuitOperationMode | mutation | protected | create | yes |
setCircuitHeatCoolMode | mutation | protected | create | yes |
setCircuitSummerWinter | mutation | protected | create | yes |
setCircuitComfortSetpoint | mutation | protected | create | yes |
setCircuitEcoSetpoint | mutation | protected | create | yes |
setCircuitMaxFlowTemp | mutation | protected | create | yes |
setDhwOperationMode | mutation | protected | create | yes |
setDhwTemperatureLevel | mutation | protected | create | yes |
setDhwChargeDuration | mutation | protected | create | yes |
startExtraHotWater | mutation | protected | create | yes |
setCircuitControlType | mutation | protected | create | yes |
setCircuitTargetTemp | mutation | protected | create | yes |
setDhwLevelTemp | mutation | protected | create | yes |
heatPumpControl.setSilentMode
- Kind: mutation —
POST /trpc/heatPumpControl.setSilentMode - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setSilentModeon your hub
Input
{ deviceId: number; mode: string }Output
voidheatPumpControl.setAwayMode
- Kind: mutation —
POST /trpc/heatPumpControl.setAwayMode - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setAwayModeon your hub
Input
{ deviceId: number; mode: string }Output
voidheatPumpControl.setAdditionalHeaterMode
- Kind: mutation —
POST /trpc/heatPumpControl.setAdditionalHeaterMode - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setAdditionalHeaterModeon your hub
Input
{ deviceId: number; mode: string }Output
voidheatPumpControl.setHolidayMode
- Kind: mutation —
POST /trpc/heatPumpControl.setHolidayMode - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setHolidayModeon your hub
Input
{ deviceId: number; mode: string }Output
voidheatPumpControl.setCircuitOperationMode
- Kind: mutation —
POST /trpc/heatPumpControl.setCircuitOperationMode - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setCircuitOperationModeon your hub
Input
{ deviceId: number; circuitId: string; mode: string }Output
voidheatPumpControl.setCircuitHeatCoolMode
- Kind: mutation —
POST /trpc/heatPumpControl.setCircuitHeatCoolMode - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setCircuitHeatCoolModeon your hub
Input
{ deviceId: number; circuitId: string; mode: string }Output
voidheatPumpControl.setCircuitSummerWinter
- Kind: mutation —
POST /trpc/heatPumpControl.setCircuitSummerWinter - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setCircuitSummerWinteron your hub
Input
{ deviceId: number; circuitId: string; mode: string }Output
voidheatPumpControl.setCircuitComfortSetpoint
- Kind: mutation —
POST /trpc/heatPumpControl.setCircuitComfortSetpoint - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setCircuitComfortSetpointon your hub
Input
{ deviceId: number; circuitId: string; temp: number }Output
voidheatPumpControl.setCircuitEcoSetpoint
- Kind: mutation —
POST /trpc/heatPumpControl.setCircuitEcoSetpoint - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setCircuitEcoSetpointon your hub
Input
{ deviceId: number; circuitId: string; temp: number }Output
voidheatPumpControl.setCircuitMaxFlowTemp
- Kind: mutation —
POST /trpc/heatPumpControl.setCircuitMaxFlowTemp - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setCircuitMaxFlowTempon your hub
Input
{ deviceId: number; circuitId: string; temp: number }Output
voidheatPumpControl.setDhwOperationMode
- Kind: mutation —
POST /trpc/heatPumpControl.setDhwOperationMode - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setDhwOperationModeon your hub
Input
{ deviceId: number; circuitId: string; mode: string }Output
voidheatPumpControl.setDhwTemperatureLevel
- Kind: mutation —
POST /trpc/heatPumpControl.setDhwTemperatureLevel - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setDhwTemperatureLevelon your hub
Input
{ deviceId: number; circuitId: string; level: string }Output
voidheatPumpControl.setDhwChargeDuration
- Kind: mutation —
POST /trpc/heatPumpControl.setDhwChargeDuration - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setDhwChargeDurationon your hub
Input
{ deviceId: number; circuitId: string; minutes: number }Output
voidheatPumpControl.startExtraHotWater
- Kind: mutation —
POST /trpc/heatPumpControl.startExtraHotWater - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.startExtraHotWateron your hub
Input
{ deviceId: number; circuitId: string }Output
voidheatPumpControl.setCircuitControlType
- Kind: mutation —
POST /trpc/heatPumpControl.setCircuitControlType - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setCircuitControlTypeon your hub
Input
{ deviceId: number; circuitId: string; controlType: string }Output
voidheatPumpControl.setCircuitTargetTemp
- Kind: mutation —
POST /trpc/heatPumpControl.setCircuitTargetTemp - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setCircuitTargetTempon your hub
Input
{ deviceId: number; circuitId: string; temp: number }Output
voidheatPumpControl.setDhwLevelTemp
- Kind: mutation —
POST /trpc/heatPumpControl.setDhwLevelTemp - Tier: protected — any signed-in principal whose scopes cover the method
- Token scope:
createon capabilityheat-pump-control, or categorydevice, or a device grant coveringdeviceId - Viewer: yes
- Try it: open
/system/api-explorer?method=heatPumpControl.setDhwLevelTempon your hub
Input
{ deviceId: number; circuitId: string; level: string; temp: number }Output
void